Home Page Company Profile Showroom
 
A.D.S. POWER SYSTEMS (P) LTD.
On-Line UPS
To inquire, Select Product/s & Click on

Product Code : 01

[Select]
Product Specification
On-Line UPS

We offer a high range of online UPS system, which are available in most advanced features such as:

  • High-frequency
  • PWM-IGBT / MOSFET based technology through zero transfer time with total line isolation providing pure sine wave output for complete and sure protection

Crest Factor

3:1 I

Power Factor

0.8 lag to Unity 1

Indications

Mains "ON", Inverter "ON", 1


"Battery Low Trip, Mains 1


Fail, Battery Low, Alarm / As I


per customer's specifications

Cooling

Natural / Forced air cooled 1

Metering

Output Volt Meter / As per 1


customer's specifications 1

Batteries

Sealed Maintenance Free / 1


Lead Acid / Tubular


for required backup[

Ambient

0°C to 45°C

Temperature

(Non-Condensing)

Charger:

CC/CV type Solid State


Charger with Boost and


Float Charging facility It


charges batteries and


delivers power to the


Inverter at 230v/415v+15%


I/P supply

D.C. Voltage

Suitable D.C. Voltage


48V, 72VT, 300V, 360V


SPECS.
Description
Technology
PWM-IGBT/MOSFET Based, Switching Frequency ≤ 15Kc/s
Input
230 volts ±15% 1Ø,
415 volts ±15% 3Ø 4 wire,
50 c/s ±3 c/s
Output
230 volts ±1% for 1Ø, or
400 volts ±1% for
3Ø on full load
THD
≤ 2% on Linear load,
≤ 5% on Non-Linear load
Wave Form
Pure sine wave
Overload
110% for 10 minutes
130% for 30 secs
150% for 5 secs
Short Circuit
Protection by electronic sensing no HRC or other types of Fuses used.
Transient
For 100% step load the out put remains within 10% of nominal output 230 volts and recovers within 3 c/s
Inverter
≥ 90%
Overall
≥ 80%
Noise Level
≤ 40 dB at 1 mtr. from UPS totally silent

SPECS.
Description
Crest Factor
3 : 1
Power Factor
0.8 lag to Unity
Indications
Mains 'ON' Inverter 'ON' Battery Low Trip, Mains Fail, Battery Low, Alarm as per customer's specifications.
Cooling
Natural Forced air cooled.
Metering
Output volt meter as per customer's specifications.
Batteries
Sealed maintenance free, Lead acid, Tubular, suitable for required backup.
Ambient Temp
0°C to 45°C Non condensing
Charger
CC/CV type solid state charger with boost and float charging facility. It charges batteries and delivers power to the inverter at 230v/415v±15% I/P supply
D.C. Voltage
Suitable D.C. voltage e.g 48V, 72V..., 300V, 360V
<< Back




 
Contact Details
 
A.D.S. POWER SYSTEMS (P) LTD.
A-1 FLATTED FACTORY COMPLEX, OKHLA PHASE-111,New Delhi - 110020, India
Phone:91-11-26435111
Fax:91-11-26435111
Send Mail   Send SMS   
Contact Now
Key Personnel
Mr. C. L. Arora (Director)
Mobile:+919311306910, +919312306910





Copyright © 2009 by A.D.S POWER SYSTEMS (P) LTD. All Rights Reserved.